Installation manual
PSC1-C-10 Installation manual V2.6
Page 168 of 173
Version: 57E
Example encoder configuration:
Validation report
Axis configuration / sensor interface
Axis 1
General parameters
Measurement length:
500
0
Type:
Rotary
Position processing:
Active
Maximum speed:
2000
0
Switch off position:
10
0
Shutdown speed:
100
0
Sensors
1
2
Type:
SSI standard
SSI standard
Format:
Binary
Binary
Count direction:
high
high
Voltage supply:
24V
24V
Resolution:
1024
Steps/1000 mm
64
Steps/1000 mm
Offset:
0
Steps
0
Steps
General parameters correctly configured
Parameters sensor 1 correct
Parameters sensor 2 correct