Once activated the auxiliary output contact closes for a set time period. You
can select the time period when programming the unit. See "Auxilliary
Output Timer".
To reset the auxiliary alarm output move the Privacy switch from its current
position, and then back again within one second. If you take longer than one
second between moving the switch and returning it then Homelink will not
reset the output. Note that you can program Homelink to send a Cancel
report when the Privacy switch is operated in this way (see “Cancel Call
(Help Arrived)” later in this Chapter).
To set the appropriate option:
1.
Start the HLEXTRA program and execute the PROGRAM command.
The display shows:
ACCOUNT NO. 1
2.
Press down arrow until the display shows the words “AUX OUTPUT
MODE”.
The display shows
(Note that this is the default):
AUX OUTPUT MODE
NONE
3.
Press the left or right arrow keys to select the option you want.
The display shows (for example):
AUX OUTPUT MODE
COMM FAIL
If you select the ALARM TRIGGER option then:
4.
Press down arrow.
The display shows
PENDANT
OFF
5.
Press the left or right arrow keys to until the bottom line of the display
shows ON in order to make the output respond to the trigger.
The display shows (for example)
PENDANT
ON
6.
Press down arrow to show each of the other triggers that you can use
to turn on the output. Use the left or right arrow keys to make the
display show ON for each trigger that you want the output to respond
to.
Auxiliary Output Timer
If you have programmed Homelink to use the auxiliary output relay then you
must also say how you want that relay to work. There are two aspects:
• Output timer - how long Homelink activates the relay for.
• Output relay - normally on or normally off. This sets the resting state of
the relay.
Note: These options do not appear if you have selected “NONE” for the Auxiliary
Output Mode.