Auxiliary Equipment
Homelink can be connected to a range of auxiliary equipment in order to
help the user. You may wish to provide auxiliary equipment if, for example,
the user spends a lot of time in a separate room to that containing the
Homelink unit. All auxiliary equipment connects to terminals provided behind
the access panel at the base of the unit. Figure 2 shows the connections
block in detail.
Use standard connecting cable for all the auxiliary equipment mentioned
below. Remove the knock out tabs from the access panel to route the wires
from the terminal.
Auxilliary output relay, clean
contacts.
Remote Emergency button (see
Note).
Extension Microphone.
NO
C
NC
+
EMG ALM
SIG
0V
5V
LS-
LS+
Extension Loudspeaker.
Note: The Remote Emergency Button must be Normally Open, close to trigger, for
example: Either
Normally Open, close switch to
trigger
+
EMG ALM
+
EMG ALM
0V
Or:
Normally Closed, open switch to
trigger.
Fig 2. Auxiliary Device Connector.
The Hard Wired Trigger input can be programmed for the following uses:
1.
Extension to the orange Emergency button.
2. Intruder/Inactivity.
3. Fire.
4. Pendant.
5. PA.
6. Low
Temperature.