496759
Page
23
Test Call Delay
To delay transmission time of the first test call enter the desired delay time in
hours. By setting this option, the unit will make a test call at the same time
each day, or number of days.
1.
Start the HLEXTRA program and execute the PROGRAM command.
The display shows:
ACCOUNT NO. 1
2.
Press down arrow until the display shows the words “TEST CALL
DELAY”.
The display shows:
TEST CALL DELAY
NONE
(Note that this is the default.)
3. Press
EXE
The display shows:
TEST CALL DELAY
_
4.
Key in the number of hours Homelink should wait before making the
first test call (max 99).
The display shows the time you enter,
for example:
TEST CALL DELAY
8_
5. Press
EXE
The displays shows the number of hours you
entered.
TEST CALL DELAY
8 HOURS
Entry/Exit Time
You can set the length of time Homelink waits before generating an intruder
alarm in “Away” mode. This time delay is important because it allows the
user to leave the protected area without triggering an alarm when they are
setting Homelink into security mode. The same time delay also allows the
user to unset Homelink when entering the protected area.
You can select a time from zero to just under 10 minutes, in steps of six
seconds. Note that setting the entry/exit time to zero disables the AWAY
button.
1.
Start the HLEXTRA program and execute the PROGRAM command.
The display shows:
ACCOUNT NO. 1
2.
Press down arrow until the display shows the words “ENTRY/EXIT
TIME”.
The display shows:
ENTRY/EXIT TIME
DISABLED