496759
Page
17
If Homelink does not receive any control signals then it ends a Speech Only
call after two minutes.
To set the communications format:
1.
Start the HLEXTRA program and execute the PROGRAM command.
The display shows:
ACCOUNT NO. 1
Note: If you want to change the comms format for another telephone number, press
the down arrow key. The display shows the destination you have selected on
the top line.
2.
Press the down arrow key until the display shows the words “COMMS
FORMAT ”.
The display shows:
COMMS FORMAT 1
SCANCOM
3.
Use right or left arrow to select the appropriate format.
The display shows the format you select,
for example:
COMMS FORMAT 1
SCANCOM FF
Reporting Map
The Reporting Map is a series of options which let you chose the alarm
types or events Homelink will report to each of the four telephone numbers.
The options available are:
Pendant
Low Battery
Local Alarm
Pendant Low Battery
Fire Alarm
Mains Fail
PA Alarm
Mains Restoral
Inactivity
Test Call
Intruder Alarm
Low Temperature
Home & Away
Cancel
For every item in the list the programmer lets you switch the option ON or
OFF for each of the four telephone numbers. When an item is ON then
Homelink will report that alarm type or event to the specified phone number.
To change the reporting map:
1.
Start the HLEXTRA program and execute the PROGRAM command.
The display shows:
ACCOUNT NO. 1
2.
Press the down arrow key until the display shows the words -
“PENDANT”.
The display shows:
PENDANT
ON ON OFF OFF
Note: The top line of the display shows the device making the report. The bottom line
of the display shows whether reporting is enabled (ON) or disabled (OFF) for
each of the four telephone numbers. Telephone number 1 is on the left, 4 on
the right.