496759
Page
25
Mains Fail Warning
This option lets you give the user an audible alarm when Homelink reports a
mains failure:
1.
Start the HLEXTRA program and execute the PROGRAM command.
The display shows:
ACCOUNT NO. 1
2.
Press down arrow until the display shows the words “MAINS FAIL”.
The display shows:
MAINS FAIL
SILENT
(Note that this is the default.)
3.
Press left (or right) arrow.
The display shows:
MAINS FAIL
AUDIBLE
Low Battery Warning
This option lets you give the user an audible warning when Homelink reports
a low battery:
1.
Start the HLEXTRA program and execute the PROGRAM command.
The display shows:
ACCOUNT NO. 1
2.
Press down arrow until the display shows the words “LOW BATTERY”.
The display shows (note that this is the default):
LOW BATTERY
SILENT
3.
Press left (or right) arrow.
The display shows:
LOW BATTERY
AUDIBLE
Line Fail Warning
If Homelink detects that the telephone line is disconnected then it starts
flashing the yellow
f
light in order to alert the user. Homelink switches the
f
light OFF when the connection is restored. The Line Fail Warning option
lets you give the user an audible warning when Homelink detects a
communications failure, in addition to the visible warning.
(To activate the auxiliary output connectors in the event of a line fault see
“Auxiliary Alarm Output”.)
1.
Start the HLEXTRA program and execute the PROGRAM command.
The display shows:
ACCOUNT NO. 1
2.
Press down arrow until the display shows the words “LINE FAIL”.
The display shows:
LINE FAIL
SILENT
3.
Press left (or right) arrow.
The display shows:
LINE FAIL
AUDIBLE