Troubleshooting | 125
Waste Collection Unit Full
The waste collection unit is full.
Replace the waste collection unit.
See section "Waste Collection Unit" for more information.
Used Waste Collection Unit
A used waste collection unit is installed.
Replace the waste collection unit.
See section "Waste Collection Unit" for more information.
Out of Printable Temperature Range
Printing is not possible because the printer is placed in a location that is too hot or cold.
Move the printer to a more suitable environment.
1. Press and hold down the [Power] key for one second.
2. Place the printer in an environment where the temperature range is between
15°C and 25°C (59°F and 77°F).
3. Turn the printer on.
If humidity is more than 54%, the upper temperature limit will be lower.
Even after the power is turned on, the printer may remain in standby mode until it
acclimates to the room temperature. If this happens, wait until the [Power] key
stops flashing and stays lit.
For details about what conditions the printer can be used under (ambient
temperature and humidity range),
see section "Checking the Installation Area" for
more information.
Printer Error
An error has occurred in the printer.
Turn the printer off, then turn it on again.
If the printer is relocated from a cold area to a warm area or the printer is placed in
a room where the temperature varies greatly, condensation may form inside the
printer causing errors. If this happens, perform the decondensation procedure. See
section "De-condensation" for more information.
If the error still does not clear after the printer acclimates to room temperature and