94
FA display Parameters
(
total 7
)
Code
Name
Setting Scope
Min
Unit
Default
ed
Value
Address
Cha
nge
FA.00
LED
displaye
d
paramet
er
selectio
n 1
Binary set
:
0
:
No displaying
1
:
Displaying
LED Units
:
Bit0
:
Output frequency(before
compensation,Hz)
Bit1
:
Output frequency ( after
compensation,Hz)
Bit2
:
Setting frequency(Hz
blink)
Bit3
:
Output current(A)
LED Tens
:
Bit0
:
Run speed(RPM)
Bit1
:
Setting speed(RPM)
Bit2
:
Reserved
Bit3
:
Reserved
LED Hundreds
:
Bit0
:
Output power
Bit1
:
Output torque
(
%
)
1
00D
A00H
○
FA01
LED
displaye
d
paramet
er
selectio
n 2
Binary set
:
0
:
No Display
1
:
Display
LED Units
:
Bit0
:
Output voltage(V)
Bit1
:
Barbus voltage
Bit2
:
Reserved
Bit3
:
AI(V)
LED Tens
:
Bit0
:
Analog closeloop
feedback (%)
Bit1
:
Analog closeloop
setting(%)
Bit2
:
External count
Bit3
:
Terminal state
LED Hundreds
:
Bit0
:
Reserved
Bit1
:
Setting pressure
1
000
A01H
○