99
FD Group
:
Professional function parameters 2
(
total 31
)
Code
Name
Setting Scope
Min
Unit
Default
ed
Value
Address
Cha
nge
FD.08
Stage 4 run
time
0.0~6500 s(min)
0.1
20.0s
D08H
○
FD.09~
FD.30
Reserved
-
- -
D09H~
D1EH
*
FE GROUP Reserves 21 parameters
FL Group
:
Fault Protection Parameters
(
total 22
)
Code
Name
Setting Scope
Min
Unit
Defaulted
Value
Address
Ch
an
ge
FL.00
Motor
overload
protection
0
:
Disable
1
:
Common motor
(
low speed
compensation
)
2
:
Varible frequency motor
(
No low speed
compensation
)
1 1 1100H
×
FL.01
Motor
overload
protection
factor
20.0
~
110% 0.1%
100.0%
1101H
×
FL.02
Stall
overvolage
0
:
Disable
1
:
Enable
1 1 1102H
×
FL.03
Stall
overvoltage
point
110.0
~
150.0% 0.1%
140.0%
1103H
×
FL.04~
FL.06 Reserved -
-
-
1104H
~
1106H
*
FL.07
Automatic
current
limit
threshold
20.0
~
200.0% 0.1%
160.0%
1107H
×
FL.08 Reserved -
-
-
1108H
*