Fault Protection Parameters
(
total 22
)
Code
Name
Setting Scope
Min
Unit
Defaulted
Value
Address
Ch
an
ge
FL.09
Action
mode of
autocurrent
limit
0
:
Constant speed invalid
1
:
Constant speed effective
2
:
Automatic current limit
valid in run state 1
3
:
Reserved
4
:
Reserved
5: Automatic current limit
valid in run state 2
1 5 1109H
×
FL.10~
FL.13
Reserved -
-
-
110AH
~110D
H
*
FL.14
Fault type
of the first
two time
0
:
No abnormal records
1
:
Overcurrent run at
acceleration (F.oC1)
2
:
Overcurrent run at
deceleration (F.oC2)
3
:
Overcurrent run at constant
speed(F.oC3)
4
:
Overvoltage run at
acceleration (F.oU1)
5
:
Overvoltage run at
deceleration (F.oU2)
6
:
Overvoltage run at constant
speed (F.oU3)
7
:
Overvoltage at control
voltage (F.PoU)
8
:
Reserved
9
:
Phaseloss at outpput
(F.oPL)
1 0 110EH
*
FL.15
Fault type
of the
previoustim
e
1 0 110EH
*