98
FD Group
:
Professional function parameters 2
(
total 31
)
Code
Name
Setting Scope
Min
Unit
Default
ed
Value
Address
Cha
nge
FD.03
Stage 2
setting
LED Units
:
0
:
Select mulit frequency
2(F8.01)
1
:
Frequnecy depends on
thefunction code of F0.02
LEDTens
:
0
:
Forward
1
:
Reverse
2
:
Subject to run command
1
00 D03H
○
FD.04
Stage 2 run
time
0.0~6500 s(min)
0.1
20.0s
D04H
○
FD.05
Stage 3
setting
LEDUnits
:
0
:
Select mulit frequency
3(F8.02)
1
:
Frequnecy depends on
thefunction code of F0.02
LEDTens
:
0
:
Forward
1
:
Reverse
2
:
Subject to run command
1
00 D05H
○
FD.06
Stage 3 run
time
0.0~6500 s(min)
0.1
20.0s
D06H
○
FD.07
Stage 4
setting
LEDUnits
:
0
:
Select mulit frequency
4(F8.03)
1
:
Frequnecy depends on
thefunction code of F0.02
LEDTens
:
0
:
Forward
1
:
Reverse
2
:
Subject to run command
1
00
D07H
○