SYSTEM MANAGEMENT
LOOP SETTING
(
This is not available in SAMS Pro Lite.)
Loop Setting [Add – Serial Communication]
Below describes how to setup Loop Setting for serial communication between the operating computer and
controller.
From the upper menu, select [System Management] > [Loop Setting].
Click Add <
> in the tool bar.
Select a [Site].
Enter the [Loop].
Select [Serial Communication] in [Communication Type].
Check [Whether to use]. If unchecked, devices connected to the selected loop will not communicate.
Set the interval of polling in [Polling Speed (ms)]. It is recommended to set to 200 ms even the optimal polling
speed may vary depending on devices.
Access controllers will communicate with the management program for data transfer in polling method. Polling
speed means the interval between data requesting polls of the SAMS Communication Server Pro to devices.
Move to the [Serial Communication] tab.
1.
2.
3.
4.
5.
6.
7.
J
8.