CLOCK & POWER MANAGEMENT
SC32442B RISC MICROPROCESSOR
7
-
12
NORMAL Mode
In Normal mode, all peripherals and the basic blocks including power management block, the CPU core, the bus
controller, the memory controller, the interrupt controller, DMA, and the external master may operate completely.
But, the clock to each peripheral, except the basic blocks, can be stopped selectively by software to reduce the
power consumption.
IDLE Mode
In IDLE mode, the clock to the CPU core is stopped except the bus controller, the memory controller, the interrupt
controller, and the power management block. To exit the IDLE mode, EINT[23:0], or RTC alarm interrupt, or the
other interrupts should be activated. (EINT is not available until GPIO block is turned on).
SLOW Mode (Non-PLL Mode)
Power consumption can be reduced in the SLOW mode by applying a slow clock and excluding the power
consumption from the PLL. The FCLK is the frequency of divide_by_n of the input clock (XTIpll or EXTCLK)
without PLL. The divider ratio is determined by SLOW_VAL in the CLKSLOW control register and CLKDIVN
control register.
Table 7-3. CLKSLOW and CLKDIVN Register Settings for SLOW Clock example
SLOW_VAL FCLK
HCLK
PCLK
UCLK
1/1
Option
(HDIVN=0)
1/2 Option
(HDIVN=1)
1/1 Option
(PDIVN=0)
1/2 Option
(PDIVN=1)
0 0 0
EXTCLK or
XTIpll / 1
EXTCLK or
XTIpll / 1
EXTCLK or
XTIpll / 2
HCLK
HCLK / 2
48 MHz
0 0 1
EXTCLK or
XTIpll / 2
EXTCLK or
XTIpll / 2
EXTCLK or
XTIpll / 4
HCLK
HCLK / 2
48 MHz
0 1 0
EXTCLK or
XTIpll / 4
EXTCLK or
XTIpll / 4
EXTCLK or
XTIpll / 8
HCLK
HCLK / 2
48 MHz
0 1 1
EXTCLK or
XTIpll / 6
EXTCLK or
XTIpll / 6
EXTCLK or
XTIpll / 12
HCLK
HCLK / 2
48 MHz
1 0 0
EXTCLK or
XTIpll / 8
EXTCLK or
XTIpll / 8
EXTCLK or
XTIpll / 16
HCLK
HCLK / 2
48 MHz
1 0 1
EXTCLK or
XTIpll / 10
EXTCLK or
XTIpll / 10
EXTCLK or
XTIpll / 20
HCLK
HCLK / 2
48 MHz
1 1 0
EXTCLK or
XTIpll / 12
EXTCLK or
XTIpll / 12
EXTCLK or
XTIpll / 24
HCLK
HCLK / 2
48 MHz
1 1 1
EXTCLK or
XTIpll / 14
EXTCLK or
XTIpll / 14
EXTCLK or
XTIpll / 28
HCLK
HCLK / 2
48 MHz
In SLOW mode, PLL will be turned off to reduce the PLL power consumption. When the PLL is turned off in the
SLOW mode and the user changes power mode from SLOW mode to NORMAL mode, then the PLL needs clock
stabilization time (PLL lock time). This PLL stabilization time is automatically inserted by the internal logic with
lock time count register. The PLL stability time will take 300us after the PLL is turned on. During PLL lock time,
the FCLK becomes SLOW clock.
Summary of Contents for SC32442B54
Page 1: ...SC32442B54 USER S MANUAL Revision 1 0 ...
Page 43: ...PRODUCT OVERVIEW SC32442B RISC MICROPROCESSOR 1 42 NOTES ...
Page 59: ...PROGRAMMER S MODEL SC32442B RISC MICROPROCESSOR 2 16 NOTES ...
Page 123: ...ARM INSTRUCTION SET SC32442B RISC MICROPROCESSOR 3 64 NOTES ...
Page 167: ...THUMB INSTRUCTION SET SC32442B RISC MICROPROCESSOR 4 44 NOTES ...
Page 187: ...MEMORY CONTROLLER SC32442B RISC MICROPROCESSOR 5 20 NOTES ...
Page 250: ...DMA SC32442B RISC MICROPROCESSOR 8 14 NOTES ...
Page 308: ...PWM TIMER SC32442B RISC MICROPROCESSOR 10 20 NOTES ...
Page 330: ...UART SC32442B RISC MICROPROCESSOR 11 22 NOTES ...
Page 417: ...SC32442B RISC MICROPROCESSOR LCD CONTROLLER 15 45 NOTES ...
Page 427: ...ADC AND TOUCH SCREEN INTERFACE SC32442B RISC MICROPROCESSOR 16 10 NOTES ...
Page 511: ...BUS PRIORITIES SC32442B RISC MICROPROCESSOR 24 2 NOTES ...
Page 562: ...K5D2G13ACM D075 Revision 1 0 December 2006 7 MCP MEMORY 2Gb 256Mb x8 NAND Flash Memory A Die ...
Page 599: ...K5D2G13ACM D075 Revision 1 0 December 2006 44 MCP MEMORY 512Mb 16Mb x32 Mobile SDRAM C Die ...