Heat Pump Installation Guide
21
When the air outlet is toward the wall.
When 3 sides of the outdoor unit are blocked by the wall.
When front and rear side of the outdoor unit is towards the wall.
300mm or mor
e
300mm or more
600mm or more
600mm or more
600mm or more
When front and rear side of
the outdoor unit is towards
the wall.
The upper part of the outdoor unit and the air outlet is opposite the wall.
1500mm
or more
600mm
or more
3000mm
or more
3000mm
or more
300mm
or more
300mm
or more
300mm
or more
300mm or mor
e
300mm or mor
e
The units must be
installed according to
distances declared,
in order to permit ac-
cessibility from each
side, either toguaran-
tee correct operation
of maintenance or re-
pairing products.The
unit’s parts must be
reachable and remov-
able completely under
safety condition.
When Installing More Than 1 Outdoor Unit
1500mm or mor
e
300mm or mor
e
600mm or more
600mm or mor
e
600mm or more