Heat Pump Installation Guide
5
Settings for Twin Heat Pump Installation & Hybrid Systems
Menu Code
Function
Default
Site Settings
4021
Enables control output for back up heat pump (0=No 1=Yes)
0
4024
Ambient temperature below which the slave will assist
+10
4031
Tells the Master unit that a backup boiler is fitted (0=No 1=Yes)
0
4032
Tells the Master unit to use the boiler as back up at the value of 4033. ( Set to 1)
0
4033
Ambient condition for the boiler to be enabled
-15
Domestic Hot Water & Heat Pump Settings
Menu Code
Function
Default
Site Settings
3011
Hot water cylinder fitted (0= No 1=Yes)
0
3021
Heat Pump Max Temp for DHW
50
3024
Min. space heating time
5
3025
Max. cylinder heating time from heat pump before turning back to heating
zones*
30
3032
Max. cylinder heating time from heat pump before turning on immersion to support
it**
20
3041
Anti-Legionella function ( 0=Off 1=Yes)
1
3042
Day of Anti-Legionella Function
Friday
3043
Start Time of Anti Legionella function
23 Hrs
3044
Target Temp
70
3045
Hold Time at 3041
10
3051
Hotwater Boost Function (0=Off 1=On)
0
3052
Hotwater Boost Timer duration x10 Min
6 (1hr)
*3025
= 200 Ltr Cylinder = 50
*3025
=300 Ltr Cylinder = 90
**3032
= 200 Ltr Cylinder = 50
**3032
=300 Ltr Cylinder = 90
Installer’s Signature
Print Name
Date
Heat Pump
Commissioning Sheet
Please register your product online
MUST BE COMPLETED AND
THEN REGISTERED ONLINE
TO COMPLETE WARRANTY