ENGLISH-42
C
o
mpleting the installati
o
n
f
Check the following after completing the installation.
Installati
o
n
Outd
oo
r unit
•
Check the external surface and the inside of the outdoor unit.
•
Is there any possibility of short circuit?
•
Is the place well-ventilated and ensures space for service?
•
Is the outdoor unit
fi
xed securely?
Ind
oo
r unit
•
Check the external surface and the inside of the indoor unit.
•
Is the place well-ventilated and ensures space for service?
•
Check if the center of the indoor unit is ensured and it is installed horizontally.
Adding refrigerant
•
Are the length and the di
ff
erence between the refrigerant pipes within the allowable
range?
•
Is the pipe properly insulated?
•
Is the quantity of the additional refrigerant correctly weighed in?
Installing the drain pipe
•
Check the drain pipe of the outdoor unit and the indoor unit.
•
Have you completed the drain test?
•
Is the drain pipe properly insulated?
Installing the wiring
•
Have you performed the earthing work 3 to the outdoor unit?
•
Is 2-core cable used?
•
Is the length of the wire is in the limited range?
•
Is the wiring route correct?