The air filter for the RG-N18000 shall be cleaned periodically (generally once every three months) by dry
cleaning or washing. Do not rub during the cleaning or washing and flat dry after the cleaning or washing.
Power Supply Maintenance
When the power supply fails, you only need to disconnect the power cable, loosen the two panel screws on the power
module, unplug the power module, replace it with a good one, and tighten the panel screws, and then connect the power
cables.
Replacing Fuses
To replace the old fuse wire with the correspondent new one, please contact the technical support representatives of
Ruijie Networks. The following table lists the specifications for the module fuses.
Module
Fuse Slot Number
Fuse Specification
F1 F
10A/125V
M18014-CM
F2 F
5A/125V
F1 F
10A/125V
M18010-CM
F2 F
5A/125V
M18014-CM II
F2
F 15A/65V
M18010-CM II
F1
F 15A/65V
M18000-24GT20SFP4XS-ED F1
F
30A/125V
M18000-48GT-ED F2 F
30A/125V
M18000-48GT-EF F2 F
30A/125V
M18000-48GT-P-ED
F2, F3, F4
F 30A/125V
M18000-44SFP4XS-ED F1
F
30A/125V
M18000-44SFP4XS-EF F1
F
30A/125V
M18000-08XS-ED F1 F
30A/125V
M18000-08XS-EF F1 F
30A/125V
M18000-48XS-DB F1 F
40A/60V
M18000-24QXS-DB
F1, F2
F 30A/125V
M18000-12QXS-DB F1 F
30A/125V
M18000-24XS4QXS-DB F1
F
40A/60V
M18000-44SFP4XS-CB
F1, F2
F 30A/125V
M18000-16XS-CB F1 F
30A/125V
M18000-40XS-CB
F1, F2
F 30A/125V
M18000-16XT-CB F1 F
30A/125V
M18000-10QXS-CB
F1, F2
F 30A/125V
RG-WALL 1600-B-ED
F1, F2
F 30A/125V
M18010-FE-CI F1
F
15A/65V
M18010-FE-D I
F1
F 30A/125V
M18010-FE-D III
F1
F 40A/60V
M18014-FE-CI F1
F
15A/65V
M18014-FE-C II
F1
F 30A/125V
M18014-FE-D I
F1
F 30A/125V
M18014-FE-D III
F1
F 30A/125V
F3, F4, F5, F6
F 5A/125V
M14-FAN
F15 F
30A/125V
F3, F4, F5, F6
F 5A/125V
M10-FAN-R
F15 F
30A/125V
F1 F
40A/60V
M10-FAN-F
F3, F4, F5, F6, F7, F8
F 5A/125V
Summary of Contents for RG-N18010
Page 1: ...RG N18000 Series Switches Hardware Installation and Reference Guide V1 08...
Page 89: ...2 RG N18010...
Page 121: ......