ECR60/ECT60 User manual
2
30V, maximum infusion or pull-out current 100mA, common cathode docking method.
Electrical characteristics
ECR60 Electrical characteristics
Product model
ECR60
ECT60
Output current
0.5 to 6A
Supply voltage
24 to 80VDC
Matching motors
Below 86 base
Encoder interface
No
Incremental orthogonal encoder, 4x
Encoder resolution
No
1000 to 65535 pulses/revolution
Photoelectric
isolation input
6 way : 2 way 5V differential input,
4 road common anode 24V input
4-way common anode 24V input
Photoelectric
isolation output
2-way photoelectric isolation output: alarm, lock, in place and universal
output
Communication
interface
RJ45
Do not exceed the scope of use described above.