ECR60/ECT60 User manual
19
0x2005 output port function
Object
dictionary
Name
Propert
y
Type
Range
The default
value
Unit
0x2005:01 Output 1 Function R/W/S
UINT
0 to 3
1
---
0x2005:02
Output 2
Function
R/W/S
UINT
0 to 3
2
---
The ECR60 contains two output ports, which are used to set the corresponding function
of the output port.
The port functionality is defined as follows:
Value
Function
0
Custom output
1
Alarm output
2
Holding gate output
3
Output in place
When set to custom output, the state of the port can be controlled by the polarity
0x2006 output port polarity
Object
dictionary
Name
Propert
y
Type
Range
The default
value
Unit
0x2006
Outputs Polarity
R/W/S
UINT
0to3
3
---
Set the normally open and normallyclosed characteristics of the output port:Bit0 is the
output port 1 polarity setting, bit1 is the output port 2 polarity setting.
0 - Often closed
1 - Always open
Bit15 to bit2
Bit1
Bit0
---
OUT2
OUT1
Summary of Contents for ECT60
Page 11: ...ECR60 ECT60 User manual 10 DC12 24V DC12 24V OUT1 DG DC12 24V OUT1 DG...
Page 15: ...ECR60 ECT60 User manual 14 1 7 Mechanical size...
Page 21: ...ECR60 ECT60 User manual 20...
Page 27: ...ECR60 ECT60 User manual 26...
Page 58: ...ECR60 ECT60 User manual 57 Probe Time Series...
Page 64: ...ECR60 ECT60 User manual 63 2 4 6 4 Method 19 2 4 6 5 Method 20 2 4 6 6 Method 21...
Page 65: ...ECR60 ECT60 User manual 64 2 4 6 7 Method 22 2 4 6 8 Method 23...
Page 66: ...ECR60 ECT60 User manual 65 2 4 6 9 Method 24 2 4 6 10 Method 25...
Page 67: ...ECR60 ECT60 User manual 66 2 4 6 11 Method 26 2 4 6 12 Method 27...
Page 68: ...ECR60 ECT60 User manual 67 2 4 6 13 Method 28 2 4 6 14 Method 29...
Page 69: ...ECR60 ECT60 User manual 68 2 4 6 15 Method 30 2 4 6 16 Method 35...
Page 71: ...ECR60 ECT60 User manual 70...