ECR60/ECT60 User manual
39
0x6041 Status Word
This object sets the probe function.
Object Type
Data Type
Access Type
PDO Mapping
Default Value
Var
UNSIGNED16
RW
Yes
0
The register bits are defined as follows:
Bit
Describe
0
Ready To Switch ON
1
Switch ON
2
Operation Enabled
3
Fault
4
Voltage Enabled
5
Quick Stop
6
Switch On Disabled
7
Warning
8
Keep
9
Remote
10
Target Reach
11-15
Keep
Bit 9: Remote
Shows whether the control word is set. This bit bit expresss control word has settled.
0x6060 operating mode
Used to set the operating mode.
Object
dictionar
y
Name
Property
Type
Range
The default
value
0x6060
Mode of Operation
RW
INTEGER8
0
The EC Series drives support the following operating modes:
Value
Mode
1
Profile Position Mode (PP)
3
Profile Velocity Mode (PV)
6
Homing Mode (HM)
Summary of Contents for ECT60
Page 11: ...ECR60 ECT60 User manual 10 DC12 24V DC12 24V OUT1 DG DC12 24V OUT1 DG...
Page 15: ...ECR60 ECT60 User manual 14 1 7 Mechanical size...
Page 21: ...ECR60 ECT60 User manual 20...
Page 27: ...ECR60 ECT60 User manual 26...
Page 58: ...ECR60 ECT60 User manual 57 Probe Time Series...
Page 64: ...ECR60 ECT60 User manual 63 2 4 6 4 Method 19 2 4 6 5 Method 20 2 4 6 6 Method 21...
Page 65: ...ECR60 ECT60 User manual 64 2 4 6 7 Method 22 2 4 6 8 Method 23...
Page 66: ...ECR60 ECT60 User manual 65 2 4 6 9 Method 24 2 4 6 10 Method 25...
Page 67: ...ECR60 ECT60 User manual 66 2 4 6 11 Method 26 2 4 6 12 Method 27...
Page 68: ...ECR60 ECT60 User manual 67 2 4 6 13 Method 28 2 4 6 14 Method 29...
Page 69: ...ECR60 ECT60 User manual 68 2 4 6 15 Method 30 2 4 6 16 Method 35...
Page 71: ...ECR60 ECT60 User manual 70...