ECR60/ECT60 User manual
23
0x2009 filter time
Object
dictionar
y
Name
Property
Type
Range
The default
value
Unit
0x2009
Filter Time
R/W/S
UINT
0to25600
6400
us
The ECR60 has a sliding average filter built in, which is used to set the time of the sliding
average filter. The greater the filtering time, the more smooth the motor starts and
stops, but the greater the response lag of the motor.
Latency - Filter Time
0x200A lock shaft time
Object
dictionar
y
Name
Property
Type
Range
The
default
value
Unit
0x2009
Soft lock Time
R/W/S
UINT
0to65535
1000
50us
The ECR60 requires locking the stepper motor for initial positioning when enabling, and
in order to reduce the jitter of the initial positioning, the ECR60 has built-in ramp locking
shaft function. This object is used to set the ramp time of the motor lock shaft when the
motor is enabling.
Lock shaft time s set value x 50us x 2 s set value x 100us
0x200B current ring parameters
Object
dictionary
Name
Propert
y
Type
Range
The
default
value
Note
0x200B:01 AutoPI enable R/W/S UINT
0 to 1
1
Identify motor parameters
while the driver is initially
positioned and automatically
calculate the PI gain
0-- No enable; 1-- enable
Summary of Contents for ECT60
Page 11: ...ECR60 ECT60 User manual 10 DC12 24V DC12 24V OUT1 DG DC12 24V OUT1 DG...
Page 15: ...ECR60 ECT60 User manual 14 1 7 Mechanical size...
Page 21: ...ECR60 ECT60 User manual 20...
Page 27: ...ECR60 ECT60 User manual 26...
Page 58: ...ECR60 ECT60 User manual 57 Probe Time Series...
Page 64: ...ECR60 ECT60 User manual 63 2 4 6 4 Method 19 2 4 6 5 Method 20 2 4 6 6 Method 21...
Page 65: ...ECR60 ECT60 User manual 64 2 4 6 7 Method 22 2 4 6 8 Method 23...
Page 66: ...ECR60 ECT60 User manual 65 2 4 6 9 Method 24 2 4 6 10 Method 25...
Page 67: ...ECR60 ECT60 User manual 66 2 4 6 11 Method 26 2 4 6 12 Method 27...
Page 68: ...ECR60 ECT60 User manual 67 2 4 6 13 Method 28 2 4 6 14 Method 29...
Page 69: ...ECR60 ECT60 User manual 68 2 4 6 15 Method 30 2 4 6 16 Method 35...
Page 71: ...ECR60 ECT60 User manual 70...