2A3/4
3-3-40
(11) Adjusting the margins for scanning an original on the contact glass
Perform the following adjustment if the margins are not correct.
U402
(P.3-3-20)
U404
(P.3-3-99)
U403
Caution: Before making the following adjustment, ensure that the above adjustments
have been made in maintenance mode.
<Procedure>
Change the setting.
Increasing the value using
the Up key makes the margin wider.
Decreasing the value using
the Down key makes the margin
narrower.
Yes
No
Start
Enter maintenance mode.
Enter "403" using the numeric keys.
Press the print key.
Set an A3 size original and
make a test copy with
the 100% magnification.
Press the print key.
The new setting
is stored.
Setting range (default)
Scanner left margin: 0 - +20 (2)
Scanner leading edge margin: 4 - +20 (6)
Scanner right margin: 0 - +20 (2)
Scanner trailing edge margin: 0 - +20 (6)
Changing the value by one moves
the margin by 0.5 mm for all.
Select the item
to be adjusted on the touch panel.
Are the margins correct?
A
B
Press the interrupt key.
Touch panel display
SCAN A MARGIN: scanner left margin
SCAN B MARGIN: scanner leading edge margin
SCAN C MARGIN: scanner right margin
SCAN D MARGIN: scanner trailing edge margin
Summary of Contents for Ri 4230
Page 3: ...SERVICE MANUAL Ri 4230 5230 ...
Page 13: ...4230 5230 S M MCA THEORY AND CONSTRUCTION SECTION I I Theory and Construction Section ...
Page 14: ...1 1 5 2A3 4 CONTENTS 1 1 Specifications 1 1 1 Specifications 1 1 1 ...
Page 100: ...4230 5230 S M MCA ELECTRICAL SECTION II II Electrical Section ...
Page 119: ......
Page 138: ......
Page 159: ...4230 5230 S M MCA III Set Up and Adjustment Section III SET UP AND ADJUSTMENT SECTION ...
Page 448: ...2A3 4 3 6 3 25 Toner scatters at the leading edge of the image See page 3 6 17 ...