2A3/4
3-3-50
( 2 ) Cleaning the drum
Clean the drum as follows when an image problems occur or if the drum is dirty.
<Precautions>
• Avoid direct sunlight and strong light when cleaning the drum.
• Dust in the air and from the cleaning pad may damage the drum during operation.
Avoid working in dusty places.
• Clean the drum entirely even if it is only dirty locally.
• Do not clean the drum with alcohol or other organic solvent.
Required supplies:
• Polishing cloth: specified synthetic cotton
• Toner
<Procedure>
1. Remove the drum from the imaging unit (see page 3-3-45).
2. Apply a polishing cloth to the drum and gently wipe the drum taking care not to
damage the surface.
3. Apply toner to another cloth and wipe the drum surface with it in the same manner.
4. Refit the drum.
5. Refit all removed parts and let the machine stand for 30 minutes.
6. Make a test copy and check the image.
Drum
Polishing cloth
Figure 3-3-60 Cleaning the drum