3-2-95
2A3/4
Maintenance
item No.
Description
U907
Checking and resetting the count value on each ejection location
Description
Displays and resets the count value of ejected sheets on each ejection
location.
Purpose
Checks the replacement period for maintenance parts. Also resets the
count value after replacing the maintenance parts.
Method
Press the print key.
* The count value on each ejection location is displayed
.
Clearing
1
Select the item for which the count value is to be reset.
* The selected item is highlighted.
* To reset the count values for all ejection locations, press ALL on the
touch panel.
2
Press the print key. The count is cleared.
Completion
To exit this maintenance item without changing the current setting, press
the stop/clear key. The screen for selecting a maintenance item is
displayed.
Display
STRAIGHT
SWITCH BACK
AUTO DUPLEX
Description
Straight ejection count
Reversed ejection count
Duplex tray ejection count