2A3/4
3-6-9
(10) Image is blurred.
(9) Black dots appear on
the image.
Causes
1. Dirty or flawed drum.
2. Deformed or worn cleaning blade.
Causes
Check procedures/corrective measures
1. Dirty or flawed drum.
Clean the drum or, if it is flawed, replace it
(see page 3-3-45).
2. Deformed or worn cleaning blade.
Replace the cleaning blade (see page
3-3-59).
Causes
1. Scanner moves erratically.
2. Deformed press roller.
3. Paper conveying section drive problem.
Causes
Check procedures/corrective measures
1. Scanner moves erratically.
2. Deformed press roller.
3. Paper conveying section drive
problem.
Check if there is any foreign matter on the
front and rear scanner rails. If any, remove it.
Replace the press roller (see page 3-3-71).
Check the gears and belts and, if necessary,
grease them.
Summary of Contents for Ri 4230
Page 3: ...SERVICE MANUAL Ri 4230 5230 ...
Page 13: ...4230 5230 S M MCA THEORY AND CONSTRUCTION SECTION I I Theory and Construction Section ...
Page 14: ...1 1 5 2A3 4 CONTENTS 1 1 Specifications 1 1 1 Specifications 1 1 1 ...
Page 100: ...4230 5230 S M MCA ELECTRICAL SECTION II II Electrical Section ...
Page 119: ......
Page 138: ......
Page 159: ...4230 5230 S M MCA III Set Up and Adjustment Section III SET UP AND ADJUSTMENT SECTION ...
Page 448: ...2A3 4 3 6 3 25 Toner scatters at the leading edge of the image See page 3 6 17 ...