4-52
Lift up the Tool Holder with the Tension Gauge (ST-002)
and measure the pressure when the pen tip leaves the
bed.
Adjust the parameter in [200gf] menu with [ ] and [ ]
keys for the pressure to be 195 to 205gf (1.9N to 2.0N).
Press [ENTER] key to save the settings.
10
11
[ENTER]
200gf
56 57
[ ] [ ]
ST-002
[ENTER]
30gf
17 16
[ ] [ ]
ST-013
9
200gf
56 57
FORCE ADJUST
200gf
CUTTING MENU
FORCE ADJUST
[ ]
[ ]
[PAUSE]
[ ]
Select [FORCE ADJUST]> [200gf], and press [PAUSE]
key to move the Tool Carriage down.
Select [30gf] menu under [FORCE ADJUST] menu.
Confirm that the force is 25 to 35gf (0.25N to 0.35N) when
the tip of the pen leaves the bed by lifting the Tool Holder
with the Dial Tension Meter (ST-013).
If the value of the force is not proper, repeat the adjustment
again.
Lift up the Tool Holder with the Dial Gauge (ST-013) and
measure the pressure when the pen tip leaves the bed.
Adjust the parameter in [30gf] menu with [ ] and [ ]
keys for the pressure to be 25 to 35gf (0.25N to 0.35N).
Press [ENTER] key to save the settings.
[ENTER]
30gf
17 16
[ ] [ ]
ST-013
8