3-55
Set the output voltage of SW Power Supply to +41V.
1. Disconnect the connector on the Servo Board.
Make sure to disconnect the connector.
3. Put the black probe into CN51-1pin (GND) and the red
probe into CN51-6pin (Vout) on the SW Power
Supply.
CN51-6pin
CN51-1pin
PROBE
8
7
Remove the 4 screws as shown in the figure and replace
with the new SW Power Supply.
Connect all the cables to the SW Power Supply.
2. Turn on the main power.
Use the Digital Multi-Meter that can measure
the direct voltage.
MAIN POWER SW
< Rear View >
CONNECTOR