4-39
5
7
4
[ ]
SERVICE MENU
CUTTING MENU
CUTTING MENU
CROPMARK SENSE
CROPMARK SENSE
OUTLEVEL CHECK
[ ]
[ ]
Min2.5V Max2.7V
[2.5V]
6
VR
Min2.5V Max2.7V
[2.5V]
Select [CUTTING MENU]> [CROPMARK SENS]>
[OUTLEVEL CHECK], and press [ENTER] key.
A Crop Mark will be printed.
After printing a Crop Mark, the Tool Carriage moves to
above the Crop Mark automatically.
Adjustment is unnecessary when the displayed MAX
voltage is 2.7 +/-0.2V.
When the MAX voltage is not proper, see the voltage
displayed with [ ] on the lower LCD. Adjust the VR on the
Tool Carriage Board so that the voltage with [ ] changes
to 2.7 +/-0.2V.
Due to the ink dry, the voltage displayed with
[ ] decreases in time. This adjustment needs
to be done quickly for smooth operation.
Perform [OUTLEVEL CHECK] again and confirm that the
MAX voltage is proper.
If it is out of range, repeat the adjustment.
Min2.5V Max2.7V
[2.5V]