4-47
Select [PRINT MENU]> [CALIB.DEFAULT]> [SETTING],
and enter the calibration value with [ ] and [ ] keys.
Press [ENTER] key to save the setting.
4
5
SERVICE MENU
PRINT MENU
PRINT MENU
CALIB.DEFAULT
[ ]
[ ]
[ ]
[ ]
[ ]
CALIB.DEFAULT
SETTING
SETTING
+0.00% +0.15%
[ ]
Calculate the amount to be calibrated with the formula as
shown in the figure.
Calibration
Value
400 -
x 100
Parameters can be entered with an increment
of 0.01%.
(MAX. +2.00% to MIN. -2.00%)
Measured
Length
Measured
Length
=