4-49
6
ADJUSTMENT
SCREW
5
The right end is the highest position of the
bed.
Turn the Adjustment Screw to adjust the space between
the Pen end and Bed to be 2.5mm to 2.6mm.
Move on to the TOOL PRESSURE ADJUSTMENT.
Click!
Move the Head Carriage to the highest position of the
bed.
Confirm that Head Carriage is connected to Tool Carriage
and lock the connected carriages.