4-13
[ ]
SELECT MODEL
VP-540
INITIALIZE ALL
SYS.PARAMETER
[ ]
INITIALIZATION
COMPLETED
+
ENTER
SERVICE REPORT
+
Roland DG Corp.
VP-540
MENU LANGUAGE
ENGLISH
LENGTH UNIT
mm > INCH
TEMP. UNIT
C > F
+
MENU
[ ]
[ ]
Other Factory Mode
SYSTEM PARAMETER INITIALIZE
All parameters will be initialized. Turn on the Sub Power SW
while pressing [ ], [ ] and [ENTER] keys to start the
machine in system parameter initialize mode.
Select the model by pressing [ ] and [ ] keys.
Press [ENTER] key to initialize the system parameter or press
the Sub Power SW more than 1 second to cancel it. The machine
turns off automatically when the initialization is completed. All
the parameters are reset to the default.
It is necessary to initialize the limit position after this initialization.
[SERVICE CALL 0101] occurs without initializing the limit
position.
LANGUAGE / UNIT
SELECTION
SERVICE REPORT PRINTING
Turn on the Sub Power SW while
pressing [ ] key to start the machine
in the service report printing mode.
The service report will be printed
automatically when the media is set
up. It prints with Black ink.
(Printing Area : W270 L360mm)
The machine turns to be the normal
mode after printing.