Chapter 7 Troubleshooting
7-4 Responding to an Error Message
[Command Not Recognized]
An emergency stop occurred because the machine
received a command that could not be interpreted
from the computer.
Pressing
pauses the machine. Because unintended
operation may occur, we recommend using the “pause” menu
displayed on the screen to select “STOP” and quit operation.
This is caused by program settings that do not match the ma-
chine’s command set. Check the program’s settings and other
values, and redo the operation from the beginning. This message
may also be displayed when a faulty connection in the connector
cable to the computer occurs. Eliminate the causes, then redo
the operation from the beginning. If this message continues to
appear, contact your authorized Roland DG Corp. dealer.
P. 40, “Starting and Quitting,” p. 50, “Stopping Cutting”
[Wrong Number of Parameters]
The number of parameters for a command received
from the computer was incorrect.
Pressing
pauses the machine. Because unintended
operation may occur, we recommend using the “pause” menu
displayed on the screen to select “STOP” and quit operation.
Check to make sure the program you’re using is compatible with
the machine.
P. 50, “Stopping Cutting”
[Bad Parameter]
The parameter for a command received from the
computer was out of range.
Pressing
pauses the machine. Because unintended
operation may occur, we recommend using the “pause” menu
displayed on the screen to select “STOP” and quit operation.
Check to make sure the program you’re using is compatible with
the machine.
P. 50, “Stopping Cutting”
Summary of Contents for EGX-350
Page 22: ...20...
Page 36: ...34 Chapter 2 Installation and Setup 2 4 Selecting the Language Switch off the power switch OFF...
Page 38: ...36...
Page 96: ...94...
Page 108: ...106...
Page 114: ...Chapter 8 Appendix 112 8 4 Main Unit Specification Dimensions of Outline Unit mm...
Page 119: ...117...
Page 120: ...118...
Page 121: ...119...
Page 122: ...120...
Page 123: ......
Page 124: ...R7 120615...