66
Chapter 4 Engraving
4-5 Cutter Installation Method 2 (No Nose Unit)
Press
.
Use
and
to select [Z0].
Press
to confirm.
The Z-axis origin is set.
Press
.
The main display appears. The coordinate values for Z is set to 0.
This completes the installation of the cutter. Go on to page 75, “Setting the XY Origin Point (Home Position)."
Storage methods for diameter-3.175 mm cutters
When you want to perform repeated use while keeping the amount of extension of the cutter tip constant, then
once you’ve decided on the amount of extension, we recommend removing the cutter holder and cutter from the
spindle unit without separating them from one another. Storing the assembly without changing the position of
the cutter holder eliminates the need to determine the amount of cutter extension each time with every use.
Note, however, that this method cannot be used with the included diameter-4.36 millimeter solid collet.
Remove the entire cutter-holder assembly
from the spindle unit.
Store without changing the position
of the cutter holder.