93 / 136 - EN -
Figure 10: Mounting the control unit bracket (only ELS 750 & 1000/ELS with eDrive)
6.2.11.
Control unit bracket: Mounting on a wall
Use the fastening material to mount the bracket of the control unit (control unit scope of delivery) in a safe, easy-to-use
place next to the kiln on the wall.
The bracket should be oriented with one fastening hole at the top and two holes at the bottom.
⇒
Mount the control unit on a suitable vertical surface which will not get hot. Choose a position where the
instrument is not exposed to direct heat from the kiln - especially when the kiln door is open.
6.3.
Power connection
6.3.1.
General information
DANGER
Risk of severe personal injury and property damage and even death from an electric shock
when installing and connecting the kiln to electrical supply lines.
⇒
The kiln should only be installed and connected to the electrical supply lines by qualified
electricians.
WARNING
Risk of serious personal injury or property damage due to incorrect connection of the kiln to
the power supply.
⇒
Make sure that the power supply is close to the kiln.
⇒
Never use an extension cable.
⇒
Make sure the power cable does not touch the hot kiln.
6.3.2.
Connecting the kiln
Kiln series
Description
Remark
ELS 150-ELS 480
without eDrive
Insert the power cable with the plug into the suitably
prepared power connection at the operating location.
ELS 750 and ELS 1000/
ELS with eDrive
ELS 750 and ELS 1000 are equipped with a switch
cabinet and a permanent power connection.
These kilns must be connected
at the operating location by a
qualified electrician.
Table 15: Connecting the kiln
Hole for bracket
Switch box
or
Summary of Contents for ELS 1000 S
Page 136: ...135 136 Notizen Notes ...
Page 137: ...136 136 Notizen Notes ...
Page 138: ...20210521 01 ...