Logic Status Word
Logic Bits
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Command
Description
x Run Ready
0 = Not Ready to Run
1 = Ready to Run
x
Active
0 = Not Active
1 = Active
x
Command Direction 0 = Reverse
1 = Forward
x
Actual Direction
0 = Reverse
1 = Forward
x
Accelerating
0 = Not Accelerating
1 = Accelerating
x
Decelerating
0 = Not Decelerating
1 = Decelerating
x
Alarm
0 = No Alarm
1 = Alarm
x
Fault
0 = No Fault
1 = Fault
x
At Setpt Spd
0 = Not at Setpoint Speed
1 = At Setpoint Speed
x
Manual
0 = Manual Mode Not Active
1 = Manual Mode Active
x
Spd Ref ID 0
00000 = Reserved
00001 = Auto Ref A
00010 = Auto Ref B
00011 = Auto Preset Speed 3
00100 = Auto Preset Speed 4
00101 = Auto Preset Speed 5
00110 = Auto Preset Speed 6
00111 = Auto Preset Speed 7
01000 = Reserved
01001 = Reserved
01010 = Reserved
01011 = Reserved
01100 = Reserved
01101 = Reserved
01110 = Reserved
01111 = Reserved
10000 = Man Port 0
10001 = Man Port 1
10010 = Man Port 2
10011 = Man Port 3
10100 = Man Port 4
10101 = Man Port 5
10110 = Man Port 6
10111 = Reserved
11000 = Reserved
11001 = Reserved
11010 = Reserved
11011 = Reserved
11100 = Reserved
11101 = Man Port 13 (Emb. ENET)
11110 = Man Port 14 (Drive Logix)
11111 = Alternate Man Ref Sel
x
Spd Ref ID 1
x
Spd Ref ID 2
x
Spd Ref ID 3
x
Spd Ref ID 4
x
Reserved
x
Running
0 = Not Running
1 = Running
x
Jogging
0 = Not Jogging
1 = Jogging
x
Stopping
0 = Not Stopping
1 = Stopping
x
DC Brake
0 = Not DC Brake
1 = DC Brake
x
DB Active
0 = Not Dynamic Brake Active
1 = Dynamic Brake Active
x
Speed Mode
0 = Not Speed Mode
1 = Speed Mode
x
Position Mode
0 = Not Position Mode
1 = Position Mode
x
Torque Mode
0 = Not Torque Mode
1 = Torque Mode
x
At Zero Speed
0 = Not at Zero Speed
1 =At Zero Speed
x
At Home
0 = Not at Home
1 = At Home
x
At Limit
0 = Not at Limit
1 = At Limit
x
Current Limit
0 = Not at Current Limit
1 = At Current Limit
x
Bus Freq Reg
0 = Not Bus Freq Reg
1 = Bus Freq Reg
x
Enable On
0 = Not Enable On
1 = Enable On
x
Motor Overload
0 = Not Motor Overload
1 = Motor Overload
x
Regen
0 = Not Regen
1= Regen