DeviceNet Objects
C-7
PowerFlex 750-Series Drive DeviceNet Option Module User Manual
Publication 750COM-UM002A-EN-P
Message Structure for Execute_Local_PCCC
The Option Module supports the following PCCC command types:
For more information regarding PCCC commands, see DF1 Protocol
and Command Set Manual (Allen-Bradley publication 1770-6.5.16)
.
Request
Response
Name
Data Type
Description
Name
Data Type
Description
CMD
USINT
Command byte
CMD
USINT
Command byte
STS
USINT
0
STS
USINT
Status byte
TNSW
UINT
Transport word
TNSW
UINT
Transport word. Same value
as the request.
FNC
USINT
Function code; not used for
all CMDs
EXT_STS USINT
Extended Status; not used
for all CMDs
PCCC_
params
ARRAY of
USINT
CMD/FNC specific
parameters
PCCC_
results
ARRAY of
USINT
CMD/FNC specific result
data
CMD
FNC
Description
0x06
0x03
Identify host and some status
0x0F
0x67
PLC-5 typed write
0x0F
0x68
PLC-5 typed read
0x0F
0x95
Encapsulate other protocol
0x0F
0xA2
SLC 500 protected typed read with 3 address fields
0x0F
0xAA
SLC 500 protected typed write with 3 address fields
0x0F
0x00
Word range read
0x0F
0x01
Word range write