Programming and Parameters
3-105
PowerFlex 700S Phase II AC Drive User Manual -
Publication 20D-UM006G-EN-P – July 2008
915
916
SL Rcv Events
Displays the received event status from
[SL Rx P0 Regis].
SL Clr Events
Set these bits to clear the corresponding event latches indicated in
[SL Rcv Events].
917
SL Rx P0 Regis
Displays received port 0 registration data, if direct received data is configured to be port 0
registration data by the Rx Direct Data Selector (Parameters
-
). Configure this
selection by using the Peer Communication window.
Default:
Min/Max:
0
-/+2147483648
RO 32-bit
Integer
918
SL Rx P1 Regis
Displays received port 1 registration data, if direct received data is configured to be port 1
registration data by the Rx Direct Data Selector (Parameters
-
). Configure this
selection by using the Peer Communication window.
Default:
Min/Max:
0
-/+2147483648
RO 32-bit
Integer
921
SL Real2DInt In
Provides the floating point (real) input to the real to integer conversion function.
Default:
Min/Max:
0.0000
-/+16.0000
✓
RW Real
922
SL Real2DInt Out
Displays the integer output of the real to integer conversion function. The value is the result of
the formula:
[SL Real2DInt In] x
[SL Mult Base].
Default:
Min/Max:
0
0/65535
RO 16-bit
Integer
923
SL Mult Base
Specifies the base for SynchLink real to integer and integer to real conversion functions.
Determines the resolution of the conversion results. You must use the same value at the
transmitting node and receiving / multiplying nodes. Enter a value that will not produce an
overflow - the product of this value and the inputs to the conversion and multiply functions
must be less than 65,536.
Default:
Min/Max:
10000.0000
0.2000/50000.0000
RW Real
924
SL Mult A In
Displays the A Multiplier Input, as a floating point (real) value. This value is divided by the
[SL Mult Base]. The source of the A Multiplier is determined by the Rx Direct Data
Selector (Parameters
-
). The possible sources are: zero,
[MulDiv 1 Mul],
[MulDiv 1 Result],
[MulDiv 2 Mul], or
[MulDiv 2 Result]. The
SynchLink Multiply function takes this input before it is converted to floating point.
Default:
Min/Max:
0.0000
0.0000/65535.0000
RO Real
925
SL Mult B In
The B Multiplier Input. This must be a floating point (real) value. The SynchLink Multiply
function takes this input after it is converted to integer.
Default:
Min/Max:
1.0000
0.25000/2.0000
✓
RW Real
926
SL Mult Out
Displays the output of the SynchLink Multiply function as a floating point (real) value. The
value is the result of the formula:
[SL Mult A In] source (integer) x
[SL Mult B
In] /
[SL Mult Base] or Par 924 [SL Mult A In] x Par 925 [SL Mult B In].
Note: The SynchLink Multiply function produces an output that is always positive.
Default:
Min/Max:
0.0000
0.0000/65535.0000
RO Real
927
SL Mult State
Displays the status of the SynchLink Multiply function.
•
Bit 0 “Local Ovflow” indicates a math overflow due to local multiply.
•
Bit 1 “Rx Ovflow” indicates a math overflow in received data.
•
Bit 3 “Ftol Ovflow” indicates a math overflow in the real to integer conversion function.
928
Rx Dir Data Type
Sets the data type for the SynchLink received direct words. If the word's bit is set the data type is floating point (real). If the bit is not set the data type is integer.
No.
Name
Description
Values
Linkab
le
R
ead-Wr
ite
Da
ta
T
ype
Options
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Op
t0
Reg
is
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
E1
Re
gi
s
E0
Re
gi
s
Default
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Bit
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9
8
7
6
5
4
3
2
1
0
0 = False
1 = True
Options
Reser
ved
Reser
ved
Reser
ved
Reser
ved
Reser
ved
Reser
ved
Reser
ved
Reser
ved
Reser
ved
Reser
ved
Reser
ved
Reser
ved
Reser
ved
Reser
ved
Reser
ved
Reser
ved
Reser
ved
Reser
ved
Reser
ved
Reser
ved
Reser
ved
Reser
ved
Reser
ved
Reser
ved
Reser
ved
Reser
ved
Reser
ved
Reser
ved
F
toI
O
vflow
Reser
ved
Rx
Ov
flo
w
Lo
cal
O
vflow
Default
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Bit
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9
8
7
6
5
4
3
2
1
0
0 = False
1 = True
Options
Re
ser
ve
d
Re
ser
ve
d
Re
ser
ve
d
Re
ser
ve
d
Re
ser
ve
d
Re
ser
ve
d
Re
ser
ve
d
Re
ser
ve
d
Re
ser
ve
d
Re
ser
ve
d
Re
ser
ve
d
Re
ser
ve
d
Re
ser
ve
d
Re
ser
ve
d
Re
ser
ve
d
Re
ser
ve
d
Re
ser
ve
d
Re
ser
ve
d
Re
ser
ve
d
Re
ser
ve
d
Re
ser
ve
d
Re
ser
ve
d
Re
ser
ve
d
Re
ser
ve
d
Re
ser
ve
d
Re
ser
ve
d
Re
ser
ve
d
Re
ser
ve
d
SL
Dir03 Rea
l
SL
Dir02 Rea
l
SL
Dir01 Rea
l
SL
Dir00 Rea
l
Default
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Bit
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9
8
7
6
5
4
3
2
1
0
0 = False
1 = True