3-94
Programming and Parameters
PowerFlex 700S Phase II AC Drive User Manual -
Publication 20D-UM006G-EN-P – July 2008
785
Posit Dect2 In
Provides the input variable for Position Watch 2. Position Watch 2 is enabled and configured
with
[Position Control] bits 18 & 19. Position Watch 2 compares this value with
[PositDetct2 Stpt] and sets bit 9 “Posit Watch2” of
[Position Status] when the
appropriate condition is satisfied. A default link connects this parameter to
[Position
Actual].
Default:
Min/Max:
0
-/+2147483648
✓
RW 32-bit
Integer
786
Xsync Status
Bit 0 “Sync Pulse” will go high for 0.5ms latching the Sync Generator inputs to the Sync Generator outputs. The period at which this bit is set is determined by
[Xsync Gen Period].
Note: Bit 1 was changed to “Reserved” for firmware version 2.04.
787
Xsync Gen Period
Sets the period for the Sync Pulse Generator. Bit 0 of
[Xsync Status] will be set for 0.5
msec and will be cleared for 0.5msec * 2[Xsync Gen Period] - 0.5 msec.
Note: Values 5 - “16 msec” and 6 - “32 msec” were added for firmware version 2.04.
Default:
Options:
1 =
0 =
1 =
2 =
3 =
“1 msec”
“0.5 msec”
4 = “8 msec”
“1 msec”
5 = “16 msec”
“2 msec”
6 = “32 msec”
“4 msec”
788
Xsync In 1
32-bit integer input of the Sync Generator. Latched to
[Xsync Out 1]. Link any 32-bit
integer parameter to this input parameter.
Note: This parameter was changed to an unsigned integer data type and linkable to
parameters that are either real or integer values for firmware version 4.001.
Default:
Min/Max:
0
0/4294967295
✓
RW 32-bit
Integer
789
Xsync Out 1
Sync Generator 32-bit output register. Latched to
[Xsync In 1] every time bit 0 “Sync
Pulse” of Par 786 [Xsync Status] is set.
Note: This parameter was changed to an unsigned integer data type and linkable to
parameters that are either real or integer values for firmware version 4.001.
Default:
Min/Max:
0
0/4294967295
RO 32-bit
Integer
790
Xsync In 2
32-bit integer input of the Sync Generator. Latched to
[Xsync Out 2]. Link any 32-bit
integer parameter to this input parameter.
Note: This parameter was changed to an unsigned integer data type and linkable to
parameters that are either real or integer values for firmware version 4.001.
Default:
Min/Max:
0
0/4294967295
✓
RW 32-bit
Integer
791
Xsync Out 2
Sync Generator 32-bit output register. Latched to
[Xsync In 2] every time bit 0 “Sync
Pulse” of
[Xsync Status] is set.
Note: This parameter was changed to an unsigned integer data type and linkable to
parameters that are either real or integer values for firmware version 4.001.
Default:
Min/Max:
0
0/4294967295
RO 32-bit
Integer
792
Xsync Out 2 Dly
Displays data of
[Xsync Out 2] from the last sync period.
Note: This parameter was changed to an unsigned integer data type and linkable to
parameters that are either real or integer values for firmware version 4.001.
Default:
Min/Max:
0
0/4294967295
RO 32-bit
Integer
793
Xsync In 3
32-bit integer input of the Sync Generator. Latched to
[Xsync Out 3]. Link any 32-bit
integer parameter to this input parameter.
Note: This parameter was changed to an unsigned integer data type and linkable to
parameters that are either real or integer values for firmware version 4.001.
Default:
Min/Max:
0
0/4294967295
✓
RW 32-bit
Integer
794
Xsync Out 3
Sync Generator 32-bit output register. Latched to
[Xsync In 3] every time bit 0 “Sync
Pulse” of
[Xsync Status] is set.
Note: This parameter was changed to an unsigned integer data type and linkable to
parameters that are either real or integer values for firmware version 4.001.
Default:
Min/Max:
0
0/4294967295
✓
RW 32-bit
Integer
795
Xsync Out 3 Dly
Displays data of
[Xsync Out 3] from the last sync period.
Note: This parameter was changed to an unsigned integer data type and linkable to
parameters that are either real or integer values for firmware version 4.001.
Default:
Min/Max:
0
0/4294967295
✓
RW 32-bit
Integer
796
Posit Gear Ratio
Sets the load side gear ratio for position control. Adjust this value when the selection of
[PositionFdbk Sel] is not 3 “Motor Fdbk”.
Calculation: Motor Encoder (Rpm) / Load Encoder (Rpm)
Note: This parameter was changed to non-linkable for firmware version 3.01. This parameter
was changed to be linkable for firmware version 3.04.
Default:
Min/Max:
1.00
0.00/9999.00
✓
RW Real
No.
Name
Description
Values
Linkab
le
R
ead-Wr
ite
Da
ta
T
ype
Options
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Sync
Un
stb
l
Sync
Lo
ss
Int
er
pIn
Sync
Rese
rv
ed
Sync
Pu
ls
e
Default
0
0
0
0
0
0
0
0
0
0
0
0
1
0
1
0
0
0
0
0
0
0
0
1
0
0
0
0
0
0
1
0
Bit
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9
8
7
6
5
4
3
2
1
0
0 = False
1 = True