3-104
Programming and Parameters
PowerFlex 700S Phase II AC Drive User Manual -
Publication 20D-UM006G-EN-P – July 2008
904
SL Node Cnfg
Set bits to configure the SynchLink node.
•
Setting bit 0 “Time Keeper” configures the local node as the Time Master.
•
Setting bit 2 “Sync Now” configures the node to synchronize with the Time Master immediately (1-2S per node) on power-up or recovery. If you do not set bit 2,
the node will stay in the fast mode, taking up to 36S per node to synchronize on power-up or recovery.
•
Setting bit 3 “Reset SL” resets SynchLink. This can be used to reset SynchLink after a configuration change instead of cycling the drive’s power.
Note: This parameter was changed to non-linkable for firmware version 3.01.
905
SL Rx CommFormat
Defines the node's communication format for receiving SynchLink data. This determines the
number of axis data, direct data and buffered data words received. Configure the format by
using the Peer Communication window in the DriveExecutive™ programming software.
•
Option 14 can be used to allow the drive to receive position data that can be used as a
position reference.
Notes: Options 6 and 16 were added for firmware version 2.04. Option 14 was added and this
parameter was changed to non-linkable for firmware version 3.01.
906
907
908
909
SL Rx DirectSel0
Determines the destination for the data received at word 0 of direct received data. Configure
the selection by using the Peer Communication window.
SL Rx DirectSel1
Determines the destination for the data received at word 1 of direct received data. Configure
the selection by using the Peer Communication window.
SL Rx DirectSel2
Determines the destination for the data received at word 2 of direct received data. Configure
the selection by using the Peer Communication window.
SL Rx DirectSel3
Determines the destination for the data received at word 3 of direct received data. Configure
the selection by using the Peer Communication window.
Notes: Options 16 - 26 were added for firmware version 2.04. These parameters were
changed to non-linkable for firmware version 3.01.
Default:
Options:
0 =
0 =
1 =
2 =
3 =
4 =
5 =
6 =
7 =
8 =
9 =
10 =
11 =
12 =
13 =
“No Data”
“No Data”
14 = “Reserved”
“SL Multiply”
15 = “Reserved”
“Event P0”
16 = “Reserved”
“Event P1”
17 = “Reserved”
“Reserved”
18 = “Reserved”
“Reserved”
19 = “Reserved”
“Reserved”
20 = “Reserved”
“Reserved”
21 = “Dir Tx Data”
“Reserved”
22 = “Dir Rx Data”
“Reserved”
23 = “E0 Accum”
“Event Status”
24 = “E1 Accum”
“Reserved”
25 = “Opt0 Accum”
“Reserved”
26 = “Opt1 Accum”
“Reserved”
910
SL Tx Comm Format
Defines the node's communication format for transmitting SynchLink data. This determines
the number of axis data words, direct data words and buffered data words transmitted.
Configure the format by using the Peer Communication window in the DriveExecutive™
programming software.
•
Value 14 can be used to allow the drive to transmit position data that can be used as a
position reference.
Note: Option 14 was added and this parameter was changed to non-linkable for firmware
version 3.01.
911
912
913
914
SL Tx DirectSel0
Determines the source type for the data transmitted by direct transmit word 0. The source type
selections are: no data, event, feedback and drive parameter.
SL Tx DirectSel1
Determines the source type for the data transmitted by direct transmit word 1. The source type
selections are: no data, event, feedback and drive parameter.
SL Tx DirectSel2
Determines the source type for the data transmitted by direct transmit word 2. The source type
selections are: no data, event, feedback and drive parameter.
SL Tx DirectSel3
Determines the source type for the data transmitted by direct transmit word 3. The source type
selections are: no data, event, feedback and drive parameter.
Note: These parameters were changed to non-linkable for firmware version 3.01.
Default:
Options:
0 =
0 =
1 =
2 =
3 =
4 =
5 =
6 =
7 =
8 =
9 =
10 =
11 =
12 =
13 =
“No Data”
“No Data”
14 = “Reserved”
“SL Multiply”
15 = “Reserved”
“Event P0”
16 = “Reserved”
“Event P1”
17 = “Reserved”
“Reserved”
18 = “Reserved”
“Reserved”
19 = “Reserved”
“Reserved”
20 = “Reserved”
“Reserved”
21 = “Dir Tx Data”
“Reserved”
22 = “Dir Rx Data”
“Reserved”
23 = “E0 Accum”
“Event Status”
24 = “E1 Accum”
“Reserved”
25 = “Opt0 Accum”
“Reserved”
26 = “Opt1 Accum”
“Reserved”
No.
Name
Description
Values
Linkab
le
R
ead-Wr
ite
Da
ta
T
ype
Options
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
t SL
Sync
No
w
Rese
rv
ed
Time K
eep
er
Default
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Bit
15 14 13 12 11 10 9
8
7
6
5
4
3
2
1
0
0 = False
1 = True
Value
Axis (A)
Direct (D)
Buffered (B)
Options 0
0
0
0
6
1
2
4
7
0
2
18
9
0
4
8
14
1
3
14
16
1
4
4
17
0
4
18
Value
Axis (A)
Direct (D)
Buffered (B)
Options 0
0
0
0
7
0
2
18
9
0
4
8
14
1
3
14
17
0
4
18