Chapter 5
FactoryTalk® View ME Software Integration
9. To assign the Expression for the blinking MultistateIndicator object Caption, select the Connections tab on the
Multistate Indicator Properties dialog (D).
10. Click Exprn (E).
11. Create the Expression (F) as shown:
• Replace InstructionName_1 with the name of the instruction or
• Replace ModuleName with the name of the Guard I/O module that this Goto Display button object
represents or
• Replace ModuleName with the name of the Analog Module’s GuardIO_Analog_AOI_Safety instance tag
name, typically ModuleName_S.
12. Replace the
Device Shortcut
with the Device Shortcut name you configured in this FactoryTalk View ME
application for your GuardLogix controller.
This expression causes the caption to blink when a demand or fault code is present on the module.
13. Repeat steps
for each Goto Display button you require.
See
Safety System Application Guide
, which illustrates a System Display with two Goto Display
buttons, one for each of the Guard I/O modules in that system.
Safety Instruction Expression
Guard I/O Expression
Analog Guard Input Expression
or
or
D
D
D
E
E
E
F
F
F