Chapter 4
SmartGuard™ 600 Controllers Logic Integration
Select Input Logic Function Blocks and Connect Inputs
1. Identify paired Safety Device blocks, and select and drag the associated Logic function blocks to the right of the
Safety Device blocks.
For this example, an AND logic block was added to provide safety logic allowing outputs when both ESTOP and
Light Curtain inputs are OK.
2. Click, drag, and drop Safety Device output pins onto the associated Logic function blocks.
3. Repeat steps 1 and 2 for all paired Safety Device blocks.
Import Zone Function Block and Connect Inputs
1. Within the Logic Editor, choose Import from the FunctionBlock menu.
2. Browse to the Files\Safety Device Routines\SmartGuard directory in the toolkit and select ZoneFB.fbd.
If you loaded the toolkit onto your personal computer’s hard drive, the default path is
C:\ProgramFiles\RA_Simplification\SafetyGuardLogix\Files\Safety Device Routines\SmartGuard.