1-14
IMSBR10-E1
Trend Recording
The measured values are printed within a width of 180 mm.
Recording Method (Pen Model)
• The measured value is updated every scan interval and continuously recorded.
• The recording colors in order from channel 01 are red, green, blue, and violet.
Recording Method (Dot Model)
• The most recent measured value is recorded with a dot every dot printing interval. The dot printing interval is
in the range of 10 s to 90 s. There are two recording methods from which you can select. One method
automatically adjusts the dot printing interval according to the chart speed so that the dots do not overlap. The
other method records at the fastest dot printing interval at all times.
• The recording colors are assigned to each set (channels 01-06, 07-12, 13-18, and 19-24) of six channels in
ascending order as follows: purple, red, green, blue, brown, and black. The recording color of each channel
can be changed among these six colors.
• For each channel, trend recording can be enabled or disabled.
<Related Topics>
Setting the dot printing interval: Section 6.1
Changing the recording color: Section 7.5
Enabling/Disabling trend recording for each channel: Section 6.6
Chart Speed
On the pen model, the chart speed can be selected from 82 settings in the range of 5 to 12000 mm/h.
On the dot model, the chart speed can be set in the range of 1 to 1500 mm/h in 1-mm steps.
The default setting is 25 mm/h.
<Related Topics>
Setting the chart speed: Section 5.4
Zone Recording
A recording zone is assigned to each channel.
Zone 1
Zone 2
Zone 3
<Related Topics>
Setting the zone recording: Section 6.4
1.4 Recording
Summary of Contents for SBR-EW180
Page 1: ...IMSBR10 E1 SBR EW180 Recorder User s Manual...
Page 2: ......
Page 14: ......
Page 233: ...3 2002...