14 June, 2002
ADF/SCANNER SECTIONS
3-5
R
e
placement
Ad
ju
s
tm
e
n
t
3.2.3 REPLACING THE REVERSE ROLLER AND TORQUE
LIMITER (PART OF THE ADF MAINTENANCE KIT)
1. Remove the separation roller cover [A].
2. Remove the clip [B] and replace the reverse roller [C] and torque limiter [D].
NOTE:
If you install all parts in the ADF maintenance kit at the same time, be sure
to reset the PM counter (ADF).
H310R050.WMF
H310R051.WMF
[A]
[B]
[C]
[D]