14 June, 2002
BIT SWITCHES
5-59
Service
Tables
G3 Switch 0A
FUNCTION
COMMENTS
0-1
Maximum allowable carrier drop
during image data reception
Bit 1 Bit 0 Value (ms)
0 0 200
0 1 400
1 0 800
1 1 Not used
These bits set the acceptable modem carrier drop
time.
Try using a longer setting if error code 0-22 is
frequent.
2
Non-ECM Carrier Drop
0: Maintain connection
1: Disconnect
Determines how the machine will respond when it
detects a drop in the carrier signal during non-
ECM communication.
3
Not used
Do not change this setting.
4
Maximum allowable frame
interval during image data
reception.
0:
5 s
1:
13 s
This bit determines the maximum interval between
each EOL signal (end-of-line) or between each
ECM frame from the other end.
Try using a longer setting if error code 0-21 is
frequent.
5
Not used
Do not change this setting.
6
Reconstruction time for the first
line in receive mode
0:
6 s
1:
12 s
When a computer controls the sending terminal,
there may be a delay in receiving page data after
the local machine accepts set-up data and sends
CFR. If this occurs, set this bit to 1 to give the
sending machine more time to send data.
Refer to error code 0-20.
7
Not used
Do not change this setting.
G3 Switch 0B
- Not used (do not change these settings)