BIT SWITCHES
14 June, 2002
5-28
System Switch 02
No FUNCTION
COMMENTS
2
Scan Router connection
0: Disabled 1: Enabled
Set this bit to 1 when you wish to use this machine
as a network scanner using Scan Router. The NIC
Fax Unit must be installed before Scan Router can
be used.
3
Substitute reception immediate
printing if paper size does not
match
0:
Disabled
1:
Enabled
1: If the paper in the trays is not the same size as
the message, the machine will print the message.
0: The machine will not print the message unless
the same size of paper is installed.
4
Automatic reset (during
communication)
0:
Disabled
1:
Enabled
1:
Standard G3 unit - The machine automatically
returns to standby mode when a page takes more
than a certain time to send (the default setting is
60 minutes).
This timer can be adjusted with RAM addresses
4803AC and 4803AD.
When the optional G3 or G4 unit is installed –
While the machine is in standby mode, it resets the
optional G3 or G4 unit at a certain interval (the
default setting is 15 min). This timer can be
adjusted with RAM addresses 4803AE and
4803AF.
For communication, when this timer expires after
the communication is finished, the machine resets
the optional G3 or G4 unit.
Cross reference
Service RAM Addresses, section 4.5.
5
Not used
Do not change these settings.
6-7 Memory read/write by RDS
Bit 7 6 Setting
0 0 Always disabled
0 1 User selectable
1 0 User selectable
1 1 Always enabled
(0,0):
All RDS systems are always locked out.
(0,1), (1,0):
Normally, RDS systems are locked
out, but the user can temporarily switch RDS on to
allow RDS operations to take place. RDS will
automatically be locked out again after a certain
time, which is stored in System Switch 03 (see
below). Note that if an RDS operation takes place,
RDS will not switch off until this time limit has
expired.
(1,1):
At any time, an RDS system can access the
machine.
System Switch 03
No FUNCTION
COMMENTS
0
to
7
Length of time that RDS is
temporarily switched on when
bits 6 and 7 of System Switch
02 are set to "User selectable"
00 - 99 hours (BCD).
This data is only valid if bits 6 and 7 of System
Switch 02 are set to "User selectable".
The default setting is 24 hours.