6.Troubleshooting
279
SC No. Level
Error Name/Error Condition/Major Cause/Solution
(An error occurred in partition "p".)
Guide for when to replace the HDD
1.
When SC863 has occurred ten times or more
The interval is short.
Repeatedly occurs in the same situation (At power-on, etc.).
Startup takes a long time when the main power is turned on.
2.
It takes a long time after main power on for the operation panel to become ready.
HDD access may be consuming time. Normal HDD access time after main power on is
about 5 seconds. If the machine is not waiting for the engine to be ready and it still takes 20
to 30 seconds or more, the HDD may be the cause. If there is a problem with the HDD,
HDD-related SCs such as SC860 and SC863 will occur frequently. Print the SC log data
and check them.
SC No. Level
Error Name/Error Condition/Major Cause/Solution
SC863-
18
D
HDD data read failure
The data written to the HDD cannot be read normally.
Bad sectors were generated during operation.
(An error occurred in partition "q".)
Guide for when to replace the HDD
1.
When SC863 has occurred ten times or more
The interval is short.
Repeatedly occurs in the same situation (At power-on, etc.).
Startup takes a long time when the main power is turned on.
2.
It takes a long time after main power on for the operation panel to become ready.
HDD access may be consuming time. Normal HDD access time after main power on is
about 5 seconds. If the machine is not waiting for the engine to be ready and it still takes 20
to 30 seconds or more, the HDD may be the cause. If there is a problem with the HDD,
HDD-related SCs such as SC860 and SC863 will occur frequently. Print the SC log data
and check them.
SC No. Level
Error Name/Error Condition/Major Cause/Solution
SC863-
19
D
HDD data read failure
The data written to the HDD cannot be read normally.
Bad sectors were generated during operation.
(An error occurred in partition "r".)
Guide for when to replace the HDD
1.
When SC863 has occurred ten times or more
Summary of Contents for M0A0
Page 2: ......
Page 10: ...8 ...
Page 12: ......
Page 34: ...2 Installation 22 9 Enter the password 10 Press OK 11 Enter the password again ...
Page 85: ...2 Installation 73 ...
Page 189: ...4 Replacement and Adjustment 177 ...
Page 203: ...5 System Maintenance 191 SP Mode Tables See Appendices ...
Page 229: ...5 System Maintenance 217 LDAP authorization information ...
Page 344: ...7 Detailed Descriptions 332 side guides from side to side ...
Page 358: ...7 Detailed Descriptions 346 ...
Page 368: ......
Page 558: ......
Page 574: ...1 Replacement and Adjustment 16 7 LCD A 4 8 Microphone A cushioning 1 ...
Page 622: ......
Page 624: ... A Short Edge Feed SEF B Long Edge Feed LEF ...
Page 626: ......
Page 632: ...1 Installation 6 ...
Page 752: ...5 Detailed Section Descriptions 126 Report Sample ...
Page 758: ...6 Specifications 132 Fax Unit Configuration Component No Remarks FCU 1 Speaker 2 ...
Page 760: ......
Page 762: ......
Page 776: ...2 Replacement and Adjustment 14 4 Detach the paper size switch from the bracket A Hook x2 ...