SC No. Type
Error Name/Error Condition/Major Cause/Solution
1.
Replace the fusing thermopile anti-condensation fan (FAN4).
2.
Re-connect the connector of the fusing thermopile anti-condensation fan
(FAN4).
3.
Replace the fusing thermopile anti-condensation fan (FAN4) harness.
4.
Replace the EGB (PCB1).
SC No.
Type
Error Name/Error Condition/Major Cause/Solution
SC541-
00
A
Fusing thermopile (TH2) disconnect error
After turning the fusing lamp on, the fusing thermopile has detected the AD value
of 0x004 (about -50 °C) or below continuously for 0.2 seconds.
•
Fusing thermopile (TH2) disconnected
•
Harness connector lose, broken, or defective
Enter the SP mode and execute fuser SC reset. Then turn the machine OFF and
ON.
If the SC occurs again, do the following steps. Check if the SC reoccurs by cycling
the power after each step.
1.
Re-connect the connector of the fusing thermopile (TH2).
2.
Replace the fusing thermopile (TH2).
3.
Replace the fusing thermopile (TH2) harness.
4.
Replace the EGB (PCB1) or/and the PSU (PCB4).
SC No.
Type
Error Name/Error Condition/Major Cause/Solution
SC542-
02
A
No reload temperature of the fusing thermopile (TH2)
After turning the fusing lamp on, the fusing thermopile has failed to reach the
reload temperature (96 °C) continuously for 8.6 seconds.
SC542-
03
A
No reload temperature of the fusing thermopile (TH2)
After reaching the reload temperature, the fusing thermopile has failed to reach the
reload temperature (96 °C) continuously for 19.8 seconds.
•
Thermopile lens dirt
•
Power supply voltage low
•
Overheating protection device triggered (blown fusing thermostat)
Enter the SP mode and execute fuser SC reset. Then turn the machine OFF and
ON.
If the SC occurs again, do the following steps. Check if the SC reoccurs by cycling
the power after each step.
1.
Check the input power source and reconnect the cable to the outlet.
2.
Replace the fusing thermopile (TH2).
Summary of Contents for M C250FW
Page 2: ......
Page 8: ......
Page 12: ......
Page 34: ...3 Preventive Maintenance 22 to remove any remaining moisture ...
Page 45: ...4 Replacement and Adjustment 33 6 Release the belt A and then remove the front cover unit B ...
Page 103: ...4 Replacement and Adjustment 91 MF model 11 Remove the fusing transport drive unit A ...
Page 112: ...4 Replacement and Adjustment 100 MF model 8 Remove the belt cover A ...
Page 183: ...5 System Maintenance 171 8 Press OK on the screen or press on the number keys to exit ...
Page 188: ...5 System Maintenance 176 Special Sender List Configuration Page Printer model ...
Page 189: ...5 System Maintenance 177 MF model ...
Page 260: ...6 Troubleshooting 248 Flowchart ...
Page 271: ...7 Detailed Descriptions 259 ...
Page 297: ...7 Detailed Descriptions 285 Boards Block Diagram Printer Model ...
Page 301: ......