7.Detailed Descriptions
278
shutdown, replace the fusing unit with a new unit.
SC No.
SC name
Monitored location
Conditions
SC543-
00
Fusing thermopile high temperature detected
(Software)
Fusing sleeve belt
(center) surface
240°C
SC544-
00
Fusing thermopile high temperature detected
(Hardware)
Fusing sleeve belt
(center) surface
250 to
260°C
SC554-
00
Fusing NC sensor high temperature detected
(Hardware)
Fusing sleeve belt
(center) surface
400 to
410°C
SC563-
00
Pressure roller thermistor (center) high
temperature detected (Software)
Pressure roller (center)
surface
248°C
SC564-
00
Pressure roller thermistor (center) high
temperature detected (Hardware)
Pressure roller (center)
surface
240 to
260°C
SC573-
00
Pressure roller thermistor (end) high
temperature detected (Software)
Pressure roller (end)
surface
248°C
SC574-
00
Pressure roller thermistor (end) high
temperature detected (Hardware)
Pressure roller (end)
surface
240 to
260°C
None
Fusing thermostat detected high temperature
Temperature of fusing
thermostat
185±3°C
Fusing Modes
Warm-up Mode
The machine enters the warm-up mode after the machine turned on. Turning the machine power on
lights the fusing lamp which raises the heat in the fusing unit to the Reload Temperature. After the
fusing unit has warmed up, the fusing motor rotates for a prescribed time to maintain the target Reload
Temperature.
Standby Mode
Within the prescribed time after the machine has reached Reload Temperature, electrical power to the
fusing lamp is switched off, and then the fusing motor switches off.
Then the fusing lamp will intermittently switch on and off in order to maintain the target Standby
Temperature. In Standby Mode the fusing motor is also switched ON/OFF intermittently.
Ready Mode
When returning from Standby Mode, the machine switches on the fusing lamp until the fusing
temperature is raised to the target Ready Temperature.
If there is no print job request issued within the prescribed time, the machine will drop down again into
Standby Mode. If the machine sends a print job request in the Standby Mode, the fusing lamp switches
on until the fusing unit reaches the target Reload Temperature, and then the job starts.
Summary of Contents for M C250FW
Page 2: ......
Page 8: ......
Page 12: ......
Page 34: ...3 Preventive Maintenance 22 to remove any remaining moisture ...
Page 45: ...4 Replacement and Adjustment 33 6 Release the belt A and then remove the front cover unit B ...
Page 103: ...4 Replacement and Adjustment 91 MF model 11 Remove the fusing transport drive unit A ...
Page 112: ...4 Replacement and Adjustment 100 MF model 8 Remove the belt cover A ...
Page 183: ...5 System Maintenance 171 8 Press OK on the screen or press on the number keys to exit ...
Page 188: ...5 System Maintenance 176 Special Sender List Configuration Page Printer model ...
Page 189: ...5 System Maintenance 177 MF model ...
Page 260: ...6 Troubleshooting 248 Flowchart ...
Page 271: ...7 Detailed Descriptions 259 ...
Page 297: ...7 Detailed Descriptions 285 Boards Block Diagram Printer Model ...
Page 301: ......