Process Control
SM 6-9
G160/G161
G160/G
161
sensor output value from each gradation of the pattern.
Step 5: V
D
, V
B
, V
L
Selection and V
REF
Adjustment
The machine makes a plot of the 10 values of M/A against the development potential that
was used to make each of the gradations. Then it makes a line through the 10 points.
Then, it finds the development potential that is necessary to put the ‘target M/A’ of toner on
the OPC.
This development potential is then used to find the best values of development bias,
charge roller voltage and laser power for the machine in its current condition. To do this, it
refers to a table in memory.
The machine also adjusts V
REF
(toner density target) at the same time. As a result, the
development gamma detected by process control will be the value stored in SP 3561 1 to 4
(do not adjust in the field unless told to do this).
After that, the transfer belt cleaning unit cleans the transfer belt.
6.3.3 TONER SUPPLY CONTROL
Toner Supply Control Modes
This machine has four toner supply control modes. They are selected with SP 3301 1 to 4.
1. Fixed supply mode
This mode is used when the TD sensor becomes defective. The amount of toner supply
can be adjusted with SP 3302 1 -4 if the image density is incorrect (the default setting is
5%).
2. Proportional control mode 1 (Pixel)
This mode is used when the TD sensor becomes defective. Only the pixel count is used to
control toner supply. The amount of toner supply can be adjusted with SP 3306 1 to 4.
3. Proportional control mode 2 (TD sensor)
CÓPIA NÃO CONTROLADA
CÓPIA NÃO CONTROLADA
Summary of Contents for G104
Page 1: ...G104 G160 G161 SERVICE MANUAL 002111MIU C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 2: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 3: ...G104 G160 G161 SERVICE MANUAL C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 4: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 5: ...G104 G160 G161 SERVICE MANUAL 002111MIU C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 6: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 8: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 10: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 12: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 20: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 24: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 26: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 28: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 29: ...INSTALLATION C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 30: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 44: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 45: ...PREVENTIVE MAINTENANCE C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 46: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 49: ...REPLACEMENT AND ADJUSTMENT C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 50: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 83: ...TROUBLESHOOTING C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 84: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 114: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 115: ...SERVICE TABLES C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 116: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 226: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 227: ...DETAILED SECTION DESCRIPTIONS C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 228: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 294: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 295: ...SPECIFICATIONS C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 296: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 303: ...G160 G161 C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 304: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 308: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 312: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 313: ...INSTALLATION C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 314: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 317: ...PREVENTIVE MAINTENANCE C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 318: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 321: ...REPLACEMENT AND ADJUSTMENT C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 322: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 333: ...TROUBLESHOOTING C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 334: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 378: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 379: ...SERVICE TABLES C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 380: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 549: ...DETAILED SECTION DESCRIPTIONS C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 550: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 577: ...SPECIFICATIONS C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 578: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 586: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 587: ...G392 PAPER FEED UNIT TYPE 4000 C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 588: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...