Process Control
SM 6-7
G160/G161
G160/G
161
(Also, V
REF
is corrected. This is used for toner supply control.)
This controls the development potential to make sure that the maximum quantity of toner
applied to the drum is constant.
If SP 3501 1 is set to "1" (Fixed), the machine does not do the potential control, but uses
the following parameters:
Development bias adjusted with SP 2212 1 to 8
Charge roller voltage adjusted with SP 2201 1 to 9
Laser power selected with SP 2105 1 to 12.
These SPs are not normally adjusted in the field.
Process Control Self-check
This machine does potential control with a procedure that is known as the process control
self-check. This procedure is done at these 9 times.
1. Initial
This starts automatically at the following times:
Immediately after the power is turned on
When the machine comes back from energy saver mode
6 hours after the power was turned on (adjusted with SP 3554 1)
If absolute humidity changes more than ± 6 g/m
3
(e.g. changes from 23°C/ 50% to
27°C/ 70%). The humidity threshold can be changed with SP 3554 2.
2. Interval: Job End
At the end of a job, process control is done after the interval of time that is set with SP 3555
1, if more than 450 prints were made after the previous process control (this number can be
adjusted with SP 3551 1 and 2).
At the end of a job, process control is done immediately, if more than 450 prints were made
after the previous process control (this number can be adjusted with SP 3551 3 and 4).
The default setting of SP 3555 1 is "0". Because of this, there is no difference between
these two processes, and the 300-print setting is not used.
After process control is done (except for forced process control), the counters are reset to
“0.”
3. Interval: Interrupt (default: 500)
If the machine makes a sequence of 500 or more color prints in the same job, printing stops
and process control is done. After it is completed, the machine continues to make prints.
The default value of 500 can be adjusted with SP 3551 5 to 6
4. Non-use Time (6 hours)
This starts before the next print job if the machine has no job for 6 hours. If the non-use
time process control is done (N) times after the user turns on the power, it will not be done.
CÓPIA NÃO CONTROLADA
CÓPIA NÃO CONTROLADA
Summary of Contents for G104
Page 1: ...G104 G160 G161 SERVICE MANUAL 002111MIU C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 2: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 3: ...G104 G160 G161 SERVICE MANUAL C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 4: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 5: ...G104 G160 G161 SERVICE MANUAL 002111MIU C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 6: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 8: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 10: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 12: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 20: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 24: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 26: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 28: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 29: ...INSTALLATION C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 30: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 44: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 45: ...PREVENTIVE MAINTENANCE C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 46: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 49: ...REPLACEMENT AND ADJUSTMENT C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 50: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 83: ...TROUBLESHOOTING C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 84: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 114: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 115: ...SERVICE TABLES C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 116: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 226: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 227: ...DETAILED SECTION DESCRIPTIONS C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 228: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 294: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 295: ...SPECIFICATIONS C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 296: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 303: ...G160 G161 C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 304: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 308: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 312: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 313: ...INSTALLATION C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 314: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 317: ...PREVENTIVE MAINTENANCE C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 318: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 321: ...REPLACEMENT AND ADJUSTMENT C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 322: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 333: ...TROUBLESHOOTING C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 334: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 378: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 379: ...SERVICE TABLES C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 380: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 549: ...DETAILED SECTION DESCRIPTIONS C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 550: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 577: ...SPECIFICATIONS C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 578: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 586: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 587: ...G392 PAPER FEED UNIT TYPE 4000 C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 588: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...